民用建筑工程室內環境檢測空氣中的甲醛、氨、氡、苯、TVOC。一、室內環境檢測檢測目的、齊齊哈爾室內環境檢測依據及范圍,檢測新建、擴建和改建的民用建筑工程室內環境污染控制是否能滿足有關規定,預防和控制室內環境污染,室內環境檢測中心保障人(ren)體健康。二、民(min)(min)用(yong)(yong)建(jian)筑(zhu)(zhu)(zhu)工(gong)(gong)程(cheng)(cheng)室(shi)內環境(jing)分類(lei)(lei)及(ji)限量(liang),民(min)(min)用(yong)(yong)建(jian)筑(zhu)(zhu)(zhu)工(gong)(gong)程(cheng)(cheng)按不(bu)同(tong)(tong)的(de)室(shi)內環境(jing)要求分為以下兩類(lei)(lei):Ⅰ類(lei)(lei)民(min)(min)用(yong)(yong)建(jian)筑(zhu)(zhu)(zhu)工(gong)(gong)程(cheng)(cheng):住宅、醫(yi)院(yuan)、老年(nian)建(jian)筑(zhu)(zhu)(zhu)、幼兒(er)園、學校(xiao)教(jiao)室(shi)等(deng)民(min)(min)用(yong)(yong)建(jian)筑(zhu)(zhu)(zhu)工(gong)(gong)程(cheng)(cheng);Ⅱ類(lei)(lei)民(min)(min)用(yong)(yong)建(jian)筑(zhu)(zhu)(zhu)工(gong)(gong)程(cheng)(cheng):辦公樓、商店、旅館、文化娛樂(le)場(chang)所、書店、圖書館、展覽(lan)館、體育館、公共交通等(deng)候室(shi)、餐(can)廳(ting)、理發(fa)店等(deng)民(min)(min)用(yong)(yong)建(jian)筑(zhu)(zhu)(zhu)工(gong)(gong)程(cheng)(cheng)。●污(wu)染物(wu)濃度測(ce)量(liang)值(zhi),除(chu)氡(dong)外均指(zhi)室(shi)內測(ce)量(liang)值(zhi)扣除(chu)同(tong)(tong)步測(ce)定(ding)的(de)室(shi)外上(shang)風向空氣測(ce)量(liang)值(zhi)(本底(di)值(zhi))后的(de)測(ce)量(liang)值(zhi)。●判定(ding)采用(yong)(yong)全數值(zhi)比(bi)較法。●檢(jian)測(ce)結果(guo)不(bu)合格時,應查找原因并采取措(cuo)施進行處理。
齊齊哈爾室內環境檢測土層孔隙水壓力變化的測試,一般用振弦式孔隙水壓力計、電測式測壓計和數字式鋼弦頻率接收儀進行測試。地下水位監測,當地下水位的升降對基坑開挖有較大影響時,應對其進行動態監測以及滲漏、冒水、管涌、沖刷的監測。 肉眼巡視與裂縫觀測,由有經驗的工程師每天進行的肉眼巡視工作是很有意義的。室內環境檢測中心主(zhu)要對地(di)(di)圈梁、鄰近建筑物(wu)及鄰近地(di)(di)面的裂(lie)縫(feng)、塌陷和支護(hu)結(jie)構工作失(shi)常、流土、滲(shen)漏或局部管涌等不(bu)良現象(xiang)的發生(sheng)和發展進行檢查、記錄和分析。上述監(jian)測(ce)項(xiang)目中,水(shui)(shui)平位移監(jian)測(ce)、沉降觀(guan)測(ce)、基(ji)坑隆起觀(guan)測(ce)、肉眼(yan)巡視(shi)和裂(lie)縫(feng)觀(guan)測(ce)等是必不(bu)可(ke)少的。其余(yu)項(xiang)目可(ke)根據工程(cheng)地(di)(di)質水(shui)(shui)文(wen)地(di)(di)質特征及設(she)計(ji)要求有選(xuan)擇地(di)(di)進行,強調量測(ce)數據與施(shi)工工況的具(ju)體(ti)施(shi)工參數配(pei)套,以形(xing)成有效(xiao)的整個監(jian)測(ce)系統(tong)。
結構實體檢驗是在結構實體上抽取試樣,齊齊哈爾室內環境檢測在現場進行檢驗或送至有相應檢測資質的檢測機構進行的檢驗。對結構實體進行檢驗,是在相應分項工程驗收合格的基礎上,對重要項目進行的驗證性檢驗,其目的是為了強化混凝土結構的施工質量驗收,真實地反映結構混凝土強度、受力鋼筋位置、結構位置與尺寸等質量指標,確保結構安全。室內環境檢測中心對涉及混凝(ning)土結構(gou)(gou)安全的(de)有代表(biao)性的(de)部位應(ying)進行(xing)結構(gou)(gou)實(shi)(shi)(shi)體檢(jian)(jian)(jian)(jian)驗(yan)(yan)。結構(gou)(gou)實(shi)(shi)(shi)體檢(jian)(jian)(jian)(jian)驗(yan)(yan)應(ying)包括混凝(ning)土強度、鋼筋保(bao)護(hu)層厚度、結構(gou)(gou)位置(zhi)與尺寸偏(pian)差以及合同約定的(de)項(xiang)目(mu);必要時可檢(jian)(jian)(jian)(jian)驗(yan)(yan)其他項(xiang)目(mu)。結構(gou)(gou)實(shi)(shi)(shi)體檢(jian)(jian)(jian)(jian)驗(yan)(yan)應(ying)由(you)監(jian)(jian)理單(dan)位組織(zhi)施工單(dan)位實(shi)(shi)(shi)施,并見證實(shi)(shi)(shi)施過程。施工單(dan)位應(ying)制(zhi)定結構(gou)(gou)實(shi)(shi)(shi)體檢(jian)(jian)(jian)(jian)驗(yan)(yan)專(zhuan)項(xiang)方案,并經(jing)監(jian)(jian)理單(dan)位審核批準后實(shi)(shi)(shi)施。除結構(gou)(gou)位置(zhi)與尺寸偏(pian)差外(wai)的(de)結構(gou)(gou)實(shi)(shi)(shi)體檢(jian)(jian)(jian)(jian)驗(yan)(yan)項(xiang)目(mu),應(ying)由(you)具(ju)有相應(ying)資(zi)質的(de)檢(jian)(jian)(jian)(jian)測機(ji)構(gou)(gou)完成。
地基基礎檢測靜載試驗基準樁、基準梁,基準樁及基準梁在載荷試驗中,齊齊哈爾室內環境檢測其使用不當將對檢測結果產生影響。所以廣大的檢測人員應引起足夠的重視,基準樁應使用小型鋼樁打入地表下一定深度,確保不受地表振動及人為因素干擾的影響,不得使用磚塊等物代替基準樁。地基基礎檢測鉆芯取樣檢測法,應采用鉆芯法,抽檢數量不得少于6孔,鉆孔深度應滿足設計要求,每孔截取一組三個芯試件;專業的室內環境檢測對于(yu)各(ge)類巖(yan)(yan)石均應進(jin)行抽檢(jian)(jian);地質條件復雜的工(gong)程還應增(zeng)加抽樣(yang)孔數(shu);對于(yu)地基基礎設計等(deng)級為(wei)甲級、乙級或巖(yan)(yan)石芯(xin)樣(yang)無法(fa)制作成芯(xin)樣(yang)試(shi)件的,還應進(jin)行巖(yan)(yan)基載荷試(shi)驗(yan);對于(yu)各(ge)類巖(yan)(yan)石均應進(jin)行抽檢(jian)(jian)。
齊齊哈爾室內環境檢測對接閃系統的防雷檢測,接閃系統是對直擊雷進行防御主要環節,它由避雷針、避雷帶、避雷網或三者共同組成。它的工作原理是先將雷電導向自身,再利用筋引線將雷電流導入大地。室內環境檢測中心除了專設避雷(lei)裝(zhuang)置(zhi)外,還可將建(jian)筑物頂層的(de)金屬構件或立(li)面作(zuo)為接閃裝(zhuang)置(zhi)。對接閃系統(tong)的(de)檢測內容主要包(bao)括:1.避雷(lei)帶的(de)材料類(lei)型(xing)和規格(ge)、敷設方式、與(yu)(yu)連接點間(jian)的(de)焊(han)接標(biao)準(zhun)(zhun)以及與(yu)(yu)引下(xia)線(xian)的(de)焊(han)接標(biao)準(zhun)(zhun);2.避雷(lei)針的(de)引下(xia)線(xian)與(yu)(yu)避雷(lei)帶、網(wang)之間(jian)的(de)等(deng)電位(wei)連接情況,是(shi)否使用金屬支架當作(zuo)引下(xia)線(xian)的(de)底(di)座等(deng);3.避雷(lei)網(wang)的(de)網(wang)格(ge)尺寸;材料類(lei)型(xing)和規格(ge);焊(han)接質(zhi)量以及與(yu)(yu)引下(xia)線(xian)的(de)焊(han)接標(biao)準(zhun)(zhun)。
結構實體檢驗是在結構實體上抽取試樣,在現場進行檢驗或送至有相應檢測資質的檢測機構進行的檢驗。齊齊哈爾室內環境檢測為保證結構實體檢驗的可行性、代表性,施工單位應編制結構性能檢驗專項方案,并經監理單位審核批準后實施。結構實體混凝土同條件養護試件強度檢驗的方案應在施工前編制,其他檢驗方案應在檢驗前編制。結構實體混凝土強度應按不同強度等級分別檢驗,室內環境檢測中心檢(jian)驗方法宜采用(yong)同條件(jian)(jian)養(yang)護(hu)試件(jian)(jian)方法;當未取得同條件(jian)(jian)養(yang)護(hu)試件(jian)(jian)強度或(huo)同條件(jian)(jian)養(yang)護(hu)試件(jian)(jian)強度不(bu)符合要求時(shi),可采用(yong)回(hui)彈-取芯(xin)法進行檢(jian)驗。鋼筋保(bao)護(hu)層(ceng)厚(hou)度、結(jie)構位(wei)置(zhi)與尺寸偏差檢(jian)驗應(ying)符合驗收(shou)規范的規定(ding)。