實話實說,現在有太多的地線只是個擺設。殊不知,僅有一根線卻沒有良好的接地體,不僅起不到地線的保護作用,還會在某個電器或線路漏電時,引起家中大面積金屬設備帶電。這樣一來,地線就不再是救命線,反倒成了索命線了。那么,究竟怎樣才能知道自己家的地線是不是妥善接地了呢?接地材料檢測公司下面介紹一下
接(jie)地線(xian)就(jiu)是直接(jie)連接(jie)地球的線(xian),也可以稱(cheng)為安全回路線(xian),危險(xian)時它就(jiu)把高壓直接(jie)轉嫁給地球,算是一(yi)根生命(ming)線(xian)。
家用(yong)電(dian)(dian)(dian)(dian)(dian)器(qi)設備由于絕緣性(xing)能不好或使用(yong)環境潮濕,會(hui)導致其外(wai)(wai)殼帶(dai)有(you)一(yi)定靜電(dian)(dian)(dian)(dian)(dian),嚴(yan)重時會(hui)發生(sheng)觸電(dian)(dian)(dian)(dian)(dian)事故(gu)。為了避(bi)免出(chu)現(xian)的(de)(de)事故(gu)可(ke)在電(dian)(dian)(dian)(dian)(dian)器(qi)的(de)(de)金(jin)屬外(wai)(wai)殼上面連(lian)接(jie)一(yi)根電(dian)(dian)(dian)(dian)(dian)線(xian),將電(dian)(dian)(dian)(dian)(dian)線(xian)的(de)(de)另一(yi)端接(jie)入(ru)(ru)大(da)地,一(yi)旦電(dian)(dian)(dian)(dian)(dian)器(qi)發生(sheng)漏(lou)電(dian)(dian)(dian)(dian)(dian)時接(jie)地線(xian)會(hui)把靜電(dian)(dian)(dian)(dian)(dian)帶(dai)入(ru)(ru)到大(da)地釋放掉(diao)。另外(wai)(wai)對于電(dian)(dian)(dian)(dian)(dian)器(qi)維修人員(yuan)在使用(yong)電(dian)(dian)(dian)(dian)(dian)烙鐵(tie)(tie)焊接(jie)電(dian)(dian)(dian)(dian)(dian)路時,有(you)時會(hui)因為電(dian)(dian)(dian)(dian)(dian)烙鐵(tie)(tie)帶(dai)電(dian)(dian)(dian)(dian)(dian)而擊穿損(sun)壞(huai)電(dian)(dian)(dian)(dian)(dian)器(qi)中的(de)(de)集(ji)成電(dian)(dian)(dian)(dian)(dian)路,這一(yi)點比較重要。使用(yong)電(dian)(dian)(dian)(dian)(dian)腦的(de)(de)朋友有(you)時也會(hui)忽略(lve)主機殼接(jie)地,其實給(gei)電(dian)(dian)(dian)(dian)(dian)腦主機殼接(jie)根地線(xian),在一(yi)定程度上可(ke)以防止(zhi)死機現(xian)象的(de)(de)出(chu)現(xian)。
在電力系統中接(jie)地(di)(di)線: 是為了在已停(ting)電的設(she)備和線路上意(yi)外(wai)地(di)(di)出(chu)現電壓時(shi)保證工(gong)作人員的重要工(gong)具。按(an)部頒(ban)規定,接(jie)地(di)(di)線必須是 25mm 2 以上裸(luo)銅軟線制成(cheng)。
方法一:萬用表測量
把(ba)萬用表(biao)調到250V~檔,分別測(ce)量零線和(he)(he)火(huo)線、地(di)線和(he)(he)火(huo)線之(zhi)間的電壓。
簡(jian)單(dan)說兩句萬用(yong)表(biao)的(de)使用(yong)方法:測量時,旋(xuan)(xuan)轉檔(dang)位旋(xuan)(xuan)鈕選擇(ze)到(dao)正確(que)檔(dang)位(250V~)。之后,把黑色表(biao)筆(bi)(bi)插(cha)入COM插(cha)孔(kong),紅色表(biao)筆(bi)(bi)插(cha)入標著“V”的(de)插(cha)孔(kong)。一(yi)只(zhi)手拿著表(biao),另一(yi)只(zhi)手像拿筷子一(yi)樣(yang)拿著兩根(gen)表(biao)筆(bi)(bi)——只(zhi)能拿塑料棒,不能接觸(chu)電線,更不能接觸(chu)前端(duan)金屬。把兩支表(biao)筆(bi)(bi)分別接觸(chu)兩根(gen)待測線——接觸(chu)順序沒有(you)要求,哪根(gen)筆(bi)(bi)接觸(chu)火線或(huo)者地線都(dou)行。
之(zhi)后我們得到了兩組數(shu)據(ju),開始進行對比。零火線之(zhi)間的電壓(ya)與地(di)(di)線和火線上(shang)的電壓(ya)相同或略大(不超(chao)過5V),證明(ming)地(di)(di)線接(jie)(jie)地(di)(di)良好,且(qie)二(er)者差距越小,證明(ming)接(jie)(jie)地(di)(di)電阻越小。反之(zhi),則接(jie)(jie)地(di)(di)體出現故障(zhang)。方法二(er):燈泡測量(liang)
如(ru)果手頭沒有萬用(yong)表,用(yong)一個燈(deng)(deng)(deng)泡(pao)也(ye)可(ke)以。實(shi)現要(yao)對(dui)燈(deng)(deng)(deng)泡(pao)處(chu)理一下,也(ye)就是接(jie)出兩根電線來,以便之(zhi)后操作——如(ru)果有閑置的燈(deng)(deng)(deng)口就更好了,直接(jie)把燈(deng)(deng)(deng)泡(pao)安裝(zhuang)在燈(deng)(deng)(deng)口上即可(ke)。
之后分別把(ba)燈泡接到零線和火線、地(di)線和火線之間(jian)(接線時記得斷(duan)電(dian)),觀察燈泡的亮(liang)度(du),分析結果。
在(zai)地(di)線接(jie)(jie)地(di)良好的(de)情況下,燈(deng)泡的(de)兩次亮度相(xiang)同。如果(guo)接(jie)(jie)地(di)體發生(sheng)故障,則燈(deng)泡不(bu)亮。如果(guo)僅(jin)僅(jin)是接(jie)(jie)地(di)電(dian)阻略大(da),那(nei)么燈(deng)泡只是稍(shao)稍(shao)變暗。
可(ke)以看出,使(shi)用(yong)燈(deng)泡測量的(de)結果(guo)不(bu)如萬(wan)(wan)用(yong)表更(geng)加準確(que)。但是(shi)即(ji)使(shi)是(shi)使(shi)用(yong)萬(wan)(wan)用(yong)表測量,也只能用(yong)“接(jie)地(di)電阻越小”、“越大”這一類含糊不(bu)清的(de)形容(rong)詞。換句話說,這兩種(zhong)方法(fa)只能粗略的(de)檢(jian)測接(jie)地(di)體(ti)(ti)是(shi)否正常,卻無法(fa)準確(que)的(de)知道(dao)接(jie)地(di)體(ti)(ti)的(de)接(jie)地(di)電阻的(de)大小。因此,如果(guo)想知道(dao)準確(que)故障,應使(shi)用(yong)更(geng)專(zhuan)業的(de)設(she)備(bei)。
方(fang)法三(san):接地電阻測(ce)試儀
這(zhe)個東西價(jia)格(ge)不菲,普通用戶沒有必要(yao)購(gou)買。一般(ban)來說(shuo),在工程驗收時,會使用這(zhe)臺設備進行檢(jian)測。
接地(di)(di)電(dian)阻(zu)測試儀,可以(yi)準確的(de)測量(liang)出(chu)地(di)(di)線的(de)接地(di)(di)電(dian)阻(zu)大小。一般我(wo)們家庭用的(de)地(di)(di)線,只要接地(di)(di)電(dian)阻(zu)不大于4歐就算合格。
注意事項
1、工作之(zhi)前(qian)必須(xu)檢查(cha)接地線(xian)(xian)。軟銅線(xian)(xian)是否(fou)斷頭(tou),螺絲連接處有無松(song)動,線(xian)(xian)鉤的彈力是否(fou)正常(chang),不符(fu)合(he)要求應及時調換或修好(hao)后(hou)再使(shi)用。
2、掛(gua)(gua)接(jie)(jie)(jie)地線(xian)前必(bi)須(xu)先驗(yan)電(dian),未驗(yan)電(dian)掛(gua)(gua)接(jie)(jie)(jie)地線(xian)是(shi)基層中較普(pu)遍的習慣(guan)性違章行為,在懸(xuan)掛(gua)(gua)時(shi)接(jie)(jie)(jie)地線(xian)道(dao)體(ti)不(bu)能和身(shen)體(ti)接(jie)(jie)(jie)觸。
3、在工作(zuo)地點兩(liang)段兩(liang)端懸掛接(jie)地線,以(yi)免用戶倒(dao)送電(dian)、感應(ying)電(dian)的可能,深受(shou)其(qi)害的例(li)子不(bu)少。
4、在打(da)接(jie)地(di)樁(zhuang)時,要撥能借地(di)體能快速疏(shu)通事故大電流(liu),保證(zheng)接(jie)地(di)質(zhi)量。
5、要愛(ai)護接地線(xian)。接地線(xian)在使(shi)用過程中(zhong)不得扭(niu)花,不用時應將軟銅(tong)線(xian)盤(pan)好(hao),接地線(xian)在拆(chai)除后,不得從空中(zhong)丟(diu)下(xia)或隨地亂(luan)摔,要用繩索傳遞(di),注意(yi)接地線(xian)的清潔(jie)工作。
6、新工作人員必須經過對接地線(xian)使(shi)用的培訓、學(xue)習(xi),考核合格(ge)后,方能(neng)單獨從(cong)事接地線(xian)操作或使(shi)用工作。
7、按不同電壓等(deng)級選用對(dui)應規(gui)格的接(jie)地線。
8、嚴禁使用(yong)其它金屬線代替接地線。
9、現場工作不(bu)得少(shao)掛(gua)接(jie)地線或(huo)者擅(shan)自變更掛(gua)接(jie)地線地點。
10、接地(di)(di)線具(ju)有雙(shuang)面性,它具(ju)有安全的作用,使用不當也(ye)會(hui)(hui)產生破(po)壞(huai)(huai)效應,所以工作完畢要及時拆(chai)除(chu)接地(di)(di)線。帶接地(di)(di)線合開關會(hui)(hui)損壞(huai)(huai)電氣設備和破(po)壞(huai)(huai)電網的穩定,會(hui)(hui)導致嚴重的惡性電氣事故。